OMNIA

Creating an Input on a Wiegand Reader Module to Generate a Lockdown/Emergency Mode For a Single APC Controller In OMNIA

Creating an Input on a Wiegand Reader Module to Generate a Lockdown/Emergency Mode For a Single APC Controller In OMNIA

How to create an input that will put the single APC Controller into Lockdown or Emergency Mode in OMNIA

Emergency
Emergency inputs are associated with fire alarms (3rd Party System Activation) or emergency call points (Manual Activation).
Activating this input will raise an Emergency event that will unlock all your
emergency doors.
In the following example, we will use the DOS (Input 1) input on a Wiegand Reader Module to activate Emergency.

Input Emergency Mode Off
Input Emergency Mode On 
Wiegand Reader Module (Input 1)

REMEMBER: DOS is always input 1 and RTE is always input 2

Lockdown 

Lockdown inputs are associated with Intruder/Active Shooter emergency call points.

Activating this input will raise a Lockdown event that will prevent the unlocking of your emergency doors.

In the following example, we will use the RTE (Input 2) input on a Wiegand Reader Module to activate Lockdown,

Input Lockdown Mode Off
Input Lockdown Mode On
Wiegand Reader Module (Input 2)

REMEMBER:  DOS is always input 1 and RTE is always input 2.

Location of Input 1 (DOS) and Input 2 (RTE) on Wiegand Reader Module for OMNIA

Note
This method will only affect the doors connected to the same system controller
as this Wiegand Reader Module. To activate Emergency mode across multiple controllers, see Configuring Emergency Input Across Multiple Controllers

Configuring an Emergency Input

These steps apply to any reader in any profile

  1. Open the Reader Profile ( Ensure this contains the correct reader being used for the input ) or Create a New Reader Profile ( Ensure you select the correct Reader being used for the input ) For This Scenario , a new Reader Profile was created. Reader Profile named Lockdown/Emergency. For Simplicity we have used the same Wiegand Reader Modules inputs for both Lockdown (Input 2)  and Emergency (Input 1). The Wiegand Reader Modules Fixed Address is 005DC20.
  2. Select Inputs then select Add Input
  3. Name the input.
  4. Select the type of input, for this case Emergency or Lockdown
  5. Select the Contact State and Input Number
  6. Save

1.  Open the Reader Profile

Located under Set-Up - Open Reader Profiles > Lockdown / Emergency, Select Readers Tab

Select the Reader the Inputs are associated with.

Select the Reader the Inputs are associated. Eg. Quick Door 3 (IN)

2. Select Inputs then select Add Inputs.

Select Inputs Tab, then Select "ADD INPUT"

3. Name the input.

4. Select the type of input, Lockdown or Emergency

Select the "type" of input, Lockdown or Emergency.

5. Select the Contact State and Input Number

REMEMBER:  DOS is always input 1 and RTE is always input 2.

Lockdown

Lockdown
Select the Contact State and Input Number

REMEMBER:  DOS is always input 1 and RTE is always input 2.

Emergency

Emergency
Select the Contact State and Input Number

REMEMBER:  DOS is always input 1 and RTE is always input 2.

Emergency and Lockdown Behavior
After creating an emergency or lockdown input, you need to decide how all your readers
will behave during Emergency Mode and Lockdown Mode.

Emergency Mode

By default, your readers will flash green but no relays will drive. The state of the relays will need to be changed.

Lockdown Mode

By default,  your readers will flash red and no relays will drive


To configure the Modes: go to, Setup>Hardware>Reader Profiles> select profile >Behavior


Steps:
1. Select the Reader Profile for the readers you wish to unlock/lockdown
2. Select the Behavior then Edit Behavior

3. Search for Emergency/Lockdown
4. Select Output States
5. Select Relay Contact State then for Emergency Mode select Drive relay in this mode, for Lockdown leave section at Do Not Drive Relay

Under Setup Tab, Select Reader Profiles > Default Reader

Select Behaviour Tab
Click "EDIT BEHAVIOR"
Select E (Emergency) or L (Lockdown)

Emergency

Emergency Relay Contact State
Drive relay in this mode

Lockdown

Lockdown Relay Contact State
Do NOT drive relay in this mode

Now all the readers in the selected Reader Profile will drive their relays during
Emergency Mode and will not drive relays in Lockdown Mode. Repeat these steps for any other required Reader Profiles.

Need further assistance?

Submit a Support Ticket

Submit a Support Ticket

FAQ

General

Can I initiate RS485 comms to a terminal from an existing IP terminal?

How to Select the Right Cable for the job

IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

Network Configuration – Best Practices

Technical Bulletins

Akuvox R20 Wiring Diagram to Wiegand Reader Module (WRM)

Finding and Adding Sigma Biometric Units to OMNIA 4.6.5

How to add a PAC Tag type to a Tag Holder

How to upgrade OMNIA hardware firmware using the OMNIA Firmware Upgrade Tool

OMNIA CSV Imports 

OMNIA Run as a Service fix for v4.x

Setting the IP address of a PMT Security Device by Directly Connecting To It with a Laptop.

Upgrading To OMNIA 4.6.5 and 2019 SQL Express With Tools

Access Control

AmanoNet

AmanoNet Back up using IB Console

AmanoNet Minimum PC Requirements and Specifications

AmanoNet System Migration Notes

Archive Tagholders in AmanoNet

Archive Transactions in AmanoNet

AutoID IP Hardware in AmanoNet

How to get PMTSecurity a copy of the AmanoNet Access Control Database

How to move AmanoNet Access Control System from one PC to another (Firebird)

IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

ImproNet/AmanoNet Database Backup: SQL

Nexxus220

Change Default Password in Nexus220
Database Migration from Nexus220/IXP220 to OMNIA
How to fix a Java SE Binary Error in Nexus220 Software
How to get a copy of a database from Nexus220 Software
How to move Nexus220 to a different PC
IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220
Move Nexus220 Access Control System from one PC to another (Firebird)
Nexus220 Firmware Upgrade
Nexus220 Notifications Configuration/Email Configuration
Nexus220 The number of doors for this license has been exceeded
Nexus220 Web Reports Using Microsoft Edge
Reduce length of time on buzzer for readers in Nexus220

Omnia

Adding a New Department in Omnia

Adding Companies to Omnia

Adding Widgets to the OMNIA Dashboard

Aperio Wireless Lock Integration

Basic Setup Guide:  Akuvox

Basic Trouble Shooting OMNIA

Batch Operations OMNIA

Change SYSDBA Password in OMNIA

Changing the IP Address of a Previously Installed Controller using the Omnia Software/URL

Configuring Web Session Timeouts in OMINA

Omnia Lite

Convert a Nexus Lite Database into OMNIA Lite Database

OMNIA LiTE Backup

PM Tronics Hardware

Amano Readers and Credentials

Change Modulation mode on XQT904 Quad Transmitter
How do I change Wiegand Output Mode on Amano readers?

Legacy Hardware

Factory Reset legacy Amano IP Cameras (sold prior to 2018)

Factory Reset Nexus220 controller

How do I factory reset the EC2 (400i) controller?

Setting IP on PMTronics Inc. Access Control Hardware

Partner Products

Partner Products

IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

Installing Cathexis Carbon and Adding a new Account

Setting Read Range on a Conekt Reader

STID Configuration

Video Management Systems

Cathexis Video (Amano Vision)

Adding Cameras into Cathexis

Cathexis Video AV (AntiVirus Exceptions)

Installing Cathexis Carbon and Adding a new Account

Quick Start Guide for Cathexis Vision Version 2025

AmanoDVMS

Which AmanoDVMS ports need to be open on my firewall?

Vision

Adding Cameras into Cathexis

AmanoVision web access user name case sensitivity usage

Adding Widgets to the OMNIA Dashboard

Adding Widgets to the OMNIA Dashboard

The OMNIA dashboard is the central hub for your access control system, the dashboard allows you to easily see useful information and make commonly used tasks available in one central page.

The OMNIA dashboard is the central hub for your access control system, the dashboard allows you to easily see useful information and make commonly used tasks available in one central page. 

From the dashboard, you can view status of doors, see live access transactions, view health aspects of the system and set up shortcuts that allow you to quickly do common tasks without having to leave the dashboard. 

Here is a list of available widgets: 

  • Access Group capacity Graph – Shows a graphical representation of people with a particular access group that are inside a given zone. 
  • Commands – Shows executable commands such as remote door open. 
  • Enrollment Graph – Total enrollments for the week and highest, lowest enrollments. 
  • Find Image – Shows the images of the person with matching id number. 
  • IP Camera – View live feed from an IP camera. 
  • Last 10 Transactions – Shows the last 10 transactions for a person. 
  • Live! – Shows a live view of access in the system. 
  • Monitor Comms Queue – Shows total queue size and total offline controllers. 
  • Monitor Door – Monitor a single door or reader on site. 
  • Quick Enroll – Enroll a person or asset. 
  • Shortcut – Shortcut loads a user defined view when clicked. 

Setting up the Dashboard. 

Once logged in to OMNIA, select the menu item at the top left ‘Dashboard’. 

To add a widget, click on the blue plus sign at the top right.   

You will be presented with a menu: 

Click on the arrow to bring up a list of available widgets. 

Select the widget that you wouls like to use: 

Here I have sellected “Commands” and Set the command to act on a site level, this will allow me to reset Anti-Passback on the site. 

Note that you can customize the widget colors. 

The dashboard optimizes itself, always trying to fill empty space, so newly created widgets will fill from the top left, you can move widgets by dragging them. 

Once your widget is where you want it, click the green check at the top right.  

This is the completed widget. From here you can put the site into LOCKDOWN (If configured), EMERGENCY LOCKDOWN (If configured) or reset APB LOCKDOWN (If configured).  

Here is an example of a well populated Dashboard: 

Need further assistance?

Submit a Support Ticket

Submit a Support Ticket

FAQ

General

Can I initiate RS485 comms to a terminal from an existing IP terminal?

How to Select the Right Cable for the job

IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

Network Configuration – Best Practices

Technical Bulletins

Akuvox R20 Wiring Diagram to Wiegand Reader Module (WRM)

Finding and Adding Sigma Biometric Units to OMNIA 4.6.5

How to add a PAC Tag type to a Tag Holder

How to upgrade OMNIA hardware firmware using the OMNIA Firmware Upgrade Tool

OMNIA CSV Imports 

OMNIA Run as a Service fix for v4.x

Setting the IP address of a PMT Security Device by Directly Connecting To It with a Laptop.

Upgrading To OMNIA 4.6.5 and 2019 SQL Express With Tools

Access Control

AmanoNet

AmanoNet Back up using IB Console

AmanoNet Minimum PC Requirements and Specifications

AmanoNet System Migration Notes

Archive Tagholders in AmanoNet

Archive Transactions in AmanoNet

AutoID IP Hardware in AmanoNet

How to get PMTSecurity a copy of the AmanoNet Access Control Database

How to move AmanoNet Access Control System from one PC to another (Firebird)

IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

ImproNet/AmanoNet Database Backup: SQL

Nexxus220

Change Default Password in Nexus220
Database Migration from Nexus220/IXP220 to OMNIA
How to fix a Java SE Binary Error in Nexus220 Software
How to get a copy of a database from Nexus220 Software
How to move Nexus220 to a different PC
IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220
Move Nexus220 Access Control System from one PC to another (Firebird)
Nexus220 Firmware Upgrade
Nexus220 Notifications Configuration/Email Configuration
Nexus220 The number of doors for this license has been exceeded
Nexus220 Web Reports Using Microsoft Edge
Reduce length of time on buzzer for readers in Nexus220

Omnia

Adding a New Department in Omnia

Adding Companies to Omnia

Aperio Wireless Lock Integration

Basic Setup Guide:  Akuvox

Basic Trouble Shooting OMNIA

Batch Operations OMNIA

Change SYSDBA Password in OMNIA

Changing the IP Address of a Previously Installed Controller using the Omnia Software/URL

Configuring Web Session Timeouts in OMINA

Create a Database for OMNIA 4.5 After Running the .iso

Omnia Lite

Convert a Nexus Lite Database into OMNIA Lite Database

OMNIA LiTE Backup

PM Tronics Hardware

Amano Readers and Credentials

Change Modulation mode on XQT904 Quad Transmitter
How do I change Wiegand Output Mode on Amano readers?

Legacy Hardware

Factory Reset legacy Amano IP Cameras (sold prior to 2018)

Factory Reset Nexus220 controller

How do I factory reset the EC2 (400i) controller?

Setting IP on PMTronics Inc. Access Control Hardware

Partner Products

Partner Products

IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

Installing Cathexis Carbon and Adding a new Account

Setting Read Range on a Conekt Reader

STID Configuration

Video Management Systems

Cathexis Video (Amano Vision)

Adding Cameras into Cathexis

Cathexis Video AV (AntiVirus Exceptions)

Installing Cathexis Carbon and Adding a new Account

Quick Start Guide for Cathexis Vision Version 2025

AmanoDVMS

Which AmanoDVMS ports need to be open on my firewall?

Vision

Adding Cameras into Cathexis

AmanoVision web access user name case sensitivity usage

OMNIA CSV Imports

OMNIA CSV Imports

Importing Tagholders into OMNIA with .CSV File

The OMNIA application provides a simple CSV import utility that can be used to import tagholders, vehicles and visitors. 

  1. Create a CSV file with headers and required data. A list of fields available for import can be seen in the table below. 
Birthday Fax (H) Postal Address (W) 
Company Fax (W) Second Name 
Department First Name Street Address (H) 
Device Serial No Gender Street Address (W 
Driver’s License No ID Number Suffix 
Email (H) Last Name Title 
Email (W) Mobile Number Vehicle Color 
Email Address Name of person visiting  
Employee No Position  
Employer Postal Address (H)  

CSV Document should resemble this: 

  1. Go to the OMNIA Server Application and select the TOOLS tab: 

Click the ‘Browse’ button and browse to your caved CSV file and select the file: 

The Browse box should now show the path to your CSV file. 

  1. Move down to Step 2: Column Mapping, before doing anything else, create a New Profile Name. In the left of the table, you will see the column headers from you CSV file, we now need to map those to fields in the database that we want to populate with the import. 

Map the source to destination by clicking on the red DESTINATION rows on the right, these are drop-downs that you can use to map your CSV source to the correct field in the database, save the profile by clicking the save button: 

  1. Move down to Step 3: Process File, press the Process button  

Review the summary at the bottom to confirm that the import was successful: 

  1. Errors or failures are usually caused by the use of special characters, extra spaces before or after records, lines between records or mismatches between sours and destination mapping. 

Need further assistance?

Submit a Support Ticket

Submit a Support Ticket

FAQ

General

Can I initiate RS485 comms to a terminal from an existing IP terminal?

How to Select the Right Cable for the job

IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

Network Configuration – Best Practices

Technical Bulletins

Akuvox R20 Wiring Diagram to Wiegand Reader Module (WRM)

Finding and Adding Sigma Biometric Units to OMNIA 4.6.5

How to add a PAC Tag type to a Tag Holder

How to upgrade OMNIA hardware firmware using the OMNIA Firmware Upgrade Tool

OMNIA CSV Imports 

OMNIA Run as a Service fix for v4.x

Setting the IP address of a PMT Security Device by Directly Connecting To It with a Laptop.

Upgrading To OMNIA 4.6.5 and 2019 SQL Express With Tools

Access Control

AmanoNet

AmanoNet Back up using IB Console

AmanoNet Minimum PC Requirements and Specifications

AmanoNet System Migration Notes

Archive Tagholders in AmanoNet

Archive Transactions in AmanoNet

AutoID IP Hardware in AmanoNet

How to get PMTSecurity a copy of the AmanoNet Access Control Database

How to move AmanoNet Access Control System from one PC to another (Firebird)

IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

ImproNet/AmanoNet Database Backup: SQL

Nexxus220

Change Default Password in Nexus220
Database Migration from Nexus220/IXP220 to OMNIA
How to fix a Java SE Binary Error in Nexus220 Software
How to get a copy of a database from Nexus220 Software
How to move Nexus220 to a different PC
IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220
Move Nexus220 Access Control System from one PC to another (Firebird)
Nexus220 Firmware Upgrade
Nexus220 Notifications Configuration/Email Configuration
Nexus220 The number of doors for this license has been exceeded
Nexus220 Web Reports Using Microsoft Edge
Reduce length of time on buzzer for readers in Nexus220

Omnia

Adding a New Department in Omnia

Adding Companies to Omnia

Adding Widgets to the OMNIA Dashboard

Aperio Wireless Lock Integration

Basic Setup Guide:  Akuvox

Basic Trouble Shooting OMNIA

Batch Operations OMNIA

Change SYSDBA Password in OMNIA

Changing the IP Address of a Previously Installed Controller using the Omnia Software/URL

Configuring Web Session Timeouts in OMINA

Omnia Lite

Convert a Nexus Lite Database into OMNIA Lite Database

OMNIA LiTE Backup

PM Tronics Hardware

Amano Readers and Credentials

Change Modulation mode on XQT904 Quad Transmitter
How do I change Wiegand Output Mode on Amano readers?

Legacy Hardware

Factory Reset legacy Amano IP Cameras (sold prior to 2018)

Factory Reset Nexus220 controller

How do I factory reset the EC2 (400i) controller?

Setting IP on PMTronics Inc. Access Control Hardware

Partner Products

Partner Products

IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

Installing Cathexis Carbon and Adding a new Account

Setting Read Range on a Conekt Reader

STID Configuration

Video Management Systems

Cathexis Video (Amano Vision)

Adding Cameras into Cathexis

Cathexis Video AV (AntiVirus Exceptions)

Installing Cathexis Carbon and Adding a new Account

Quick Start Guide for Cathexis Vision Version 2025

AmanoDVMS

Which AmanoDVMS ports need to be open on my firewall?

Vision

Adding Cameras into Cathexis

AmanoVision web access user name case sensitivity usage

How to Print Tags in OMNIA

How to Print Tags in OMNIA

Printing Tags in OMNIA

NOTE:

Install your printer to the PC, before installing the Plugin Manager

To print tags in OMNIA you must install the OMNIA Plugin Mgr, Update the Printer Persistence File, and Create a Tag Template

See Knowledgebase article titled, How to Install the OMNIA Plugin Mgr.

How to Install The OMNIA Plugin Manager

Seen Knowledgebase article, How to Use the OMNIA Card Designer.

How to Use The OMNIA Card Designer

Select your printer in the Plugin Manager

Right click the OMNIA Plugin Manager Icon, select Plugin Status

From the Settings Tab, use the dropdown to select your printer click save settings.

Log into the OMNIA URL , if currently logged in, log out then back in.

Go to Enrollment\Tagholder and select a Tagholder

In the Tagholder Screen, Select Tags, then Select the Tag Code

Select Printing, the Print Window will appear. Select your previously designed Card Template by using the arrow and selecting the desired template

After Selecting the Template, Select Print

The print job will be sent to the Print Queue.

After the OMNIA Plugin Mgr has been installed, you may have to update the Printer Persistence.xml file.

          Update the Printer Persistence.xml file located at:

          C:\Program Files (x86)\OMNIA\OMNIA Plugin Manager\print\META-INF.

Open the file in Notepad to edit the path and the name of the Database.

Use the IP address of the Database or localhost if the Database resides on the PC you are wanting to print tags from.

Change the Database Name from Portal to OMNIA

NOTE: There are two (2) Locations on the Printing Persistence File that need to be updated.

Using IP of SQL Server

Using LOCALHOST

    Need further assistance?

    Submit a Support Ticket

    Submit a Support Ticket

    FAQ

    General

    Can I initiate RS485 comms to a terminal from an existing IP terminal?

    How to Select the Right Cable for the job

    IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

    Network Configuration – Best Practices

    Technical Bulletins

    Akuvox R20 Wiring Diagram to Wiegand Reader Module (WRM)

    Finding and Adding Sigma Biometric Units to OMNIA 4.6.5

    How to add a PAC Tag type to a Tag Holder

    How to upgrade OMNIA hardware firmware using the OMNIA Firmware Upgrade Tool

    OMNIA CSV Imports 

    OMNIA Run as a Service fix for v4.x

    Setting the IP address of a PMT Security Device by Directly Connecting To It with a Laptop.

    Upgrading To OMNIA 4.6.5 and 2019 SQL Express With Tools

    Access Control

    AmanoNet

    AmanoNet Back up using IB Console

    AmanoNet Minimum PC Requirements and Specifications

    AmanoNet System Migration Notes

    Archive Tagholders in AmanoNet

    Archive Transactions in AmanoNet

    AutoID IP Hardware in AmanoNet

    How to get PMTSecurity a copy of the AmanoNet Access Control Database

    How to move AmanoNet Access Control System from one PC to another (Firebird)

    IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

    ImproNet/AmanoNet Database Backup: SQL

    Nexxus220

    Change Default Password in Nexus220
    Database Migration from Nexus220/IXP220 to OMNIA
    How to fix a Java SE Binary Error in Nexus220 Software
    How to get a copy of a database from Nexus220 Software
    How to move Nexus220 to a different PC
    IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220
    Move Nexus220 Access Control System from one PC to another (Firebird)
    Nexus220 Firmware Upgrade
    Nexus220 Notifications Configuration/Email Configuration
    Nexus220 The number of doors for this license has been exceeded
    Nexus220 Web Reports Using Microsoft Edge
    Reduce length of time on buzzer for readers in Nexus220

    Omnia

    Adding a New Department in Omnia

    Adding Companies to Omnia

    Adding Widgets to the OMNIA Dashboard

    Aperio Wireless Lock Integration

    Basic Setup Guide:  Akuvox

    Basic Trouble Shooting OMNIA

    Batch Operations OMNIA

    Change SYSDBA Password in OMNIA

    Changing the IP Address of a Previously Installed Controller using the Omnia Software/URL

    Configuring Web Session Timeouts in OMINA

    Omnia Lite

    Convert a Nexus Lite Database into OMNIA Lite Database

    OMNIA LiTE Backup

    PM Tronics Hardware

    Amano Readers and Credentials

    Change Modulation mode on XQT904 Quad Transmitter
    How do I change Wiegand Output Mode on Amano readers?

    Legacy Hardware

    Factory Reset legacy Amano IP Cameras (sold prior to 2018)

    Factory Reset Nexus220 controller

    How do I factory reset the EC2 (400i) controller?

    Setting IP on PMTronics Inc. Access Control Hardware

    Partner Products

    Partner Products

    IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

    Installing Cathexis Carbon and Adding a new Account

    Setting Read Range on a Conekt Reader

    STID Configuration

    Video Management Systems

    Cathexis Video (Amano Vision)

    Adding Cameras into Cathexis

    Cathexis Video AV (AntiVirus Exceptions)

    Installing Cathexis Carbon and Adding a new Account

    Quick Start Guide for Cathexis Vision Version 2025

    AmanoDVMS

    Which AmanoDVMS ports need to be open on my firewall?

    Vision

    Adding Cameras into Cathexis

    AmanoVision web access user name case sensitivity usage

    Updating OMNIA Printer Persistence File

    Updating OMNIA Printer Persistence File

    If the Card Designer Program does not connect to the OMNIA Database.

    After the OMNIA Plugin Mgr has been installed, you may have to update the Printer Persistence.xml file. er the OMNIA Plugin Mgr has been installed, you may have to update the Printer Persistence.xml file.

              Update the Printer Persistence.xml file located at:

              C:\Program Files (x86)\OMNIA\OMNIA Plugin Manager\print\META-INF.

    Open the file in Notepad to edit the path and the name of the Database.

    Use the IP address of the Database or localhost if the Database resides on the PC you are wanting to print tags from.

    Change the Database Name from Portal to OMNIA

    NOTE: There are two (2) Locations on the Printing Persistence File that need to be updated.

    Using IP of SQL Server

    Using LOCALHOST

    Need further assistance?

    Submit a Support Ticket

    Submit a Support Ticket

    FAQ

    General

    Can I initiate RS485 comms to a terminal from an existing IP terminal?

    How to Select the Right Cable for the job

    IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

    Network Configuration – Best Practices

    Technical Bulletins

    Akuvox R20 Wiring Diagram to Wiegand Reader Module (WRM)

    Finding and Adding Sigma Biometric Units to OMNIA 4.6.5

    How to add a PAC Tag type to a Tag Holder

    How to upgrade OMNIA hardware firmware using the OMNIA Firmware Upgrade Tool

    OMNIA CSV Imports 

    OMNIA Run as a Service fix for v4.x

    Setting the IP address of a PMT Security Device by Directly Connecting To It with a Laptop.

    Upgrading To OMNIA 4.6.5 and 2019 SQL Express With Tools

    Access Control

    AmanoNet

    AmanoNet Back up using IB Console

    AmanoNet Minimum PC Requirements and Specifications

    AmanoNet System Migration Notes

    Archive Tagholders in AmanoNet

    Archive Transactions in AmanoNet

    AutoID IP Hardware in AmanoNet

    How to get PMTSecurity a copy of the AmanoNet Access Control Database

    How to move AmanoNet Access Control System from one PC to another (Firebird)

    IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

    ImproNet/AmanoNet Database Backup: SQL

    Nexxus220

    Change Default Password in Nexus220
    Database Migration from Nexus220/IXP220 to OMNIA
    How to fix a Java SE Binary Error in Nexus220 Software
    How to get a copy of a database from Nexus220 Software
    How to move Nexus220 to a different PC
    IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220
    Move Nexus220 Access Control System from one PC to another (Firebird)
    Nexus220 Firmware Upgrade
    Nexus220 Notifications Configuration/Email Configuration
    Nexus220 The number of doors for this license has been exceeded
    Nexus220 Web Reports Using Microsoft Edge
    Reduce length of time on buzzer for readers in Nexus220

    Omnia

    Adding a New Department in Omnia

    Adding Companies to Omnia

    Adding Widgets to the OMNIA Dashboard

    Aperio Wireless Lock Integration

    Basic Setup Guide:  Akuvox

    Basic Trouble Shooting OMNIA

    Batch Operations OMNIA

    Change SYSDBA Password in OMNIA

    Changing the IP Address of a Previously Installed Controller using the Omnia Software/URL

    Configuring Web Session Timeouts in OMINA

    Omnia Lite

    Convert a Nexus Lite Database into OMNIA Lite Database

    OMNIA LiTE Backup

    PM Tronics Hardware

    Amano Readers and Credentials

    Change Modulation mode on XQT904 Quad Transmitter
    How do I change Wiegand Output Mode on Amano readers?

    Legacy Hardware

    Factory Reset legacy Amano IP Cameras (sold prior to 2018)

    Factory Reset Nexus220 controller

    How do I factory reset the EC2 (400i) controller?

    Setting IP on PMTronics Inc. Access Control Hardware

    Partner Products

    Partner Products

    IDEMIA Sigma Lite Readers NOT compatible for use in AmanoNet or Nexus220

    Installing Cathexis Carbon and Adding a new Account

    Setting Read Range on a Conekt Reader

    STID Configuration

    Video Management Systems

    Cathexis Video (Amano Vision)

    Adding Cameras into Cathexis

    Cathexis Video AV (AntiVirus Exceptions)

    Installing Cathexis Carbon and Adding a new Account

    Quick Start Guide for Cathexis Vision Version 2025

    AmanoDVMS

    Which AmanoDVMS ports need to be open on my firewall?

    Vision

    Adding Cameras into Cathexis

    AmanoVision web access user name case sensitivity usage

    • « Go to Previous Page
    • Page 1
    • Interim pages omitted …
    • Page 4
    • Page 5
    • Page 6
    • Page 7
    • Page 8
    • Interim pages omitted …
    • Page 12
    • Go to Next Page »

    PMT Security

    Copyright © 2025 PMT Security, Inc. | All Rights Reserved